AKCP LoRa 5 Dry Contact Inputs
The wireless 5 dry contact sensor gives multiple inputs to monitor third party devices. Useful for wireless monitoring of alarm panels, UPS, or any device with a dry contact output. Communicate dry contact status over the LoRa™ network to the gateway.
Dry Contact Input Monitoring
The wireless 5 dry contact sensor gives multiple inputs to monitor third party devices. Useful for wireless monitoring of alarm panels, UPS, or any device with a dry contact output. Communicate dry contact status over the LoRa™ network to the gateway. Extend dry contacts across a network wirelessly to actuate relays. When a dry contact status changes its status is instantly broadcast to the LoRa™ gateway, which can signal a relay to actuate, alarm to sound, or change the state of a digital I/O controller. Easy installation and pairing with AKCP LoRa™ gateway.
Sensor Options
- Battery powered, with 10 year guaranteed battery life*
- USB powered
- USB powered with backup internal battery
- Custom sensor cable length to position sensor and antenna in optimal position.
Dimension | Ø77 X 47mm |
Mounting | DIN Rail, Magnetic, Wall Hanging |
Power source: | Internal non-removable batteries or via micro-USB port |
Power Consumption: | Average 12 mWatt Up to 10 years of battery life |
Status Indication | LED indication for Mode |
Components | Manufactured using highly integrated, low power surface mount technology to ensure long term reliability. |
Operating Environment | Temperature : Min. -35° C – Max.80° C Humidity: Min. 20% – Max. 80% (Non-Condensing) |
LoRa (R) Radio | – EU : 863~870Mhz Max TX Power +14dBm Duty Cycle 1% – US : 902~915Mhz Max TX Power +20dBm – AS: 920~925Mhz Max TX Power +14dBm Duty Cycle 1% |
Certification | FCC Part15C, CE EN300220-2 |
Environment monitoring | |
Temperature | |
Measurement Range: | -40°C to +75°C -40°F to +167°F |
Measurement Resolution: | 0.1°C increments 0.2°F increments |
Measurement Accuracy: | Maximum ±0.3 at -40ºC, minimum ±0.3 at +25ºC and ±0.3 at +75ºC Maximum ±0.6 at -40ºF, minimum ±0.6 at +25ºC and ±0.6 at +167ºF |
Humidity | |
Measurement range: | 0 to 100% Relative humidity |
Resolution: | 1%RH increments, 0.01%RH sensor reading |
Accuracy at: | 25°C ±2%RH |
Dry Contact (LBTD) | 1x Discrete Dry Contact inputs |
Input | Switch type dry contact: open or close Edge counter |